AR2220路由器(qì)E1線路連接
2015/3/3 17:00:50點擊:
問題描述
華為AR2220路由器(qì)配置2E1-M闆卡連接運營商E1線路,與遠端的cisco設備互聯,線路聯通(tōng)後端口無法UP。
告警信息
通(tōng)過檢查端口的狀态發現端口物理(lǐ)狀态及line protocol狀态都是down,本端地址無法正常ping通(tōng)對端地址。
AKL-DR-WAN-RT-001-E1 3/0/0]dis controller e1 3/0/0
E1 3/0/0 current state : DOWN
Description : Shanghai International Curcuit
Basic Configuration:
Work Mode is E1 Unframed, Cable type is 75 Ohm unbalanced.
Frame-format is None, Line Code is Hdb3.
Source Clock is Slave, Data-coding is Normal.
Idle code is 7E, Itf type is 7E, Itf number is 4.
Loopback is Not Set.
Alarm State:
Receiver alarm state is Loss-of-Signal.
Transmitter is sending remote alarm.
Pulse density violation detected.
AKL-DR-WAN-RT-001-E1 3/0/0]dis controller e1 3/0/0
E1 3/0/0 current state : DOWN
Description : Shanghai International Curcuit
Basic Configuration:
Work Mode is E1 Unframed, Cable type is 75 Ohm unbalanced.
Frame-format is None, Line Code is Hdb3.
Source Clock is Slave, Data-coding is Normal.
Idle code is 7E, Itf type is 7E, Itf number is 4.
Loopback is Not Set.
Alarm State:
Receiver alarm state is Loss-of-Signal.
Transmitter is sending remote alarm.
Pulse density violation detected.
處理(lǐ)過程
1. 查看設備的型号及軟件版本,display version,display device檢查設備的版本及辦卡狀态,确定版本是V200R005,闆卡加載狀态正常。
<Huawei> display device
AR2240's Device status:
Slot Sub Type Online Power Register Alarm Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3 - 2E1 Present PowerOn Registered Normal NA
2. 确定連接線纜已經連接,運營商的光端機已經連接,線路類型為RJ48線纜轉DB9端口的平衡線纜(120歐)。
3. 檢查配置信息,确認配置信息正确。
controller E1 3/0/0
using e1
description Shanghai International Curcuit
undo detect-ais
line-termination 120-ohm
#
interface Serial3/0/0:0
link-protocol hdlc
description Shanghai International Curcuit
ip address x.x.x.x x.x.x.x
4. 檢查接口信息及log信息,發現E1端口下面有(yǒu)錯誤告警信息。懷疑是運營商線路或連接跳(tiào)線故障。
[AKL-DR-WAN-RT-001-E1 3/0/0]dis controller e1 3/0/0
E1 3/0/0 current state : DOWN
Description : International Curcuit
Basic Configuration:
Work Mode is E1 Unframed, Cable type is 120 Ohm balanced.
Frame-format is None, Line Code is Hdb3.
Source Clock is Slave, Data-coding is Normal.
Idle code is 7E, Itf type is 7E, Itf number is 4.
Loopback is Not Set.
Alarm State:
Receiver alarm state is Loss-of-Signal.
Transmitter is sending remote alarm.
Pulse density violation detected.
Historical Statistics:
Data in current interval (567 seconds elapsed):
37158345 Line Code Violations, 0 Path Code Violations
567 Slip Secs, 0 Fr Loss Secs, 567 Line Err Secs, 0 Degraded Mins
567 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 567 Unavail Secs
Total Data (last 24 hours):
59117268 Line Code Violations, 0 Path Code Violations
912 Slip Secs, 53 Fr Loss Secs, 912 Line Err Secs, 0 Degraded Mins
912 Errored Secs, 0 Bursty Err Secs, 53 Severely Err Secs, 912 Unavail Secs
[AKL-DR-WAN-RT-001-Serial3/0/0:0]dis int s3/0/0:0
Serial3/0/0:0 current state : DOWN
Line protocol current state : DOWN
Description:Shanghai International Curcuit
Route Port,The Maximum Transmit Unit is 1500, Hold timer is 10(sec)
Derived from E1 3/0/0, Unframed mode, baudrate is 2048000 bps
Internet Address is x.x.x.x/y
Link layer protocol is nonstandard HDLC
Current system time: 2014-12-23 07:45:48
Last 300 seconds input rate 0 bytes/sec 0 bits/sec 0 packets/sec
Last 300 seconds output rate 0 bytes/sec 0 bits/sec 0 packets/sec
Input: 0 packets, 0 bytes
Total Error: 0, No Buffers: 0
runts: 0, Giants: 0
CRC: 0, Alignments: 0
Aborts: 0
Output: 0 packets, 0 bytes
Total Error: 0, No Buffers: 0
Giants: 0
Input bandwidth utilization : 0%
Output bandwidth utilization : 0%
5. 要求運營商在端口連接側對跳(tiào)線打環測試,測試結果顯示端口為up,确定闆卡和(hé)設備運行(xíng)正常,故障在物理(lǐ)線路側。
6. 繼續在運營商光端機端口打環進行(xíng)測試,測試結果顯示接口為down。确定是運營商光端機端口連接故障,調整端口連接。故障排除。
<Huawei> display device
AR2240's Device status:
Slot Sub Type Online Power Register Alarm Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3 - 2E1 Present PowerOn Registered Normal NA
2. 确定連接線纜已經連接,運營商的光端機已經連接,線路類型為RJ48線纜轉DB9端口的平衡線纜(120歐)。
3. 檢查配置信息,确認配置信息正确。
controller E1 3/0/0
using e1
description Shanghai International Curcuit
undo detect-ais
line-termination 120-ohm
#
interface Serial3/0/0:0
link-protocol hdlc
description Shanghai International Curcuit
ip address x.x.x.x x.x.x.x
4. 檢查接口信息及log信息,發現E1端口下面有(yǒu)錯誤告警信息。懷疑是運營商線路或連接跳(tiào)線故障。
[AKL-DR-WAN-RT-001-E1 3/0/0]dis controller e1 3/0/0
E1 3/0/0 current state : DOWN
Description : International Curcuit
Basic Configuration:
Work Mode is E1 Unframed, Cable type is 120 Ohm balanced.
Frame-format is None, Line Code is Hdb3.
Source Clock is Slave, Data-coding is Normal.
Idle code is 7E, Itf type is 7E, Itf number is 4.
Loopback is Not Set.
Alarm State:
Receiver alarm state is Loss-of-Signal.
Transmitter is sending remote alarm.
Pulse density violation detected.
Historical Statistics:
Data in current interval (567 seconds elapsed):
37158345 Line Code Violations, 0 Path Code Violations
567 Slip Secs, 0 Fr Loss Secs, 567 Line Err Secs, 0 Degraded Mins
567 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 567 Unavail Secs
Total Data (last 24 hours):
59117268 Line Code Violations, 0 Path Code Violations
912 Slip Secs, 53 Fr Loss Secs, 912 Line Err Secs, 0 Degraded Mins
912 Errored Secs, 0 Bursty Err Secs, 53 Severely Err Secs, 912 Unavail Secs
[AKL-DR-WAN-RT-001-Serial3/0/0:0]dis int s3/0/0:0
Serial3/0/0:0 current state : DOWN
Line protocol current state : DOWN
Description:Shanghai International Curcuit
Route Port,The Maximum Transmit Unit is 1500, Hold timer is 10(sec)
Derived from E1 3/0/0, Unframed mode, baudrate is 2048000 bps
Internet Address is x.x.x.x/y
Link layer protocol is nonstandard HDLC
Current system time: 2014-12-23 07:45:48
Last 300 seconds input rate 0 bytes/sec 0 bits/sec 0 packets/sec
Last 300 seconds output rate 0 bytes/sec 0 bits/sec 0 packets/sec
Input: 0 packets, 0 bytes
Total Error: 0, No Buffers: 0
runts: 0, Giants: 0
CRC: 0, Alignments: 0
Aborts: 0
Output: 0 packets, 0 bytes
Total Error: 0, No Buffers: 0
Giants: 0
Input bandwidth utilization : 0%
Output bandwidth utilization : 0%
5. 要求運營商在端口連接側對跳(tiào)線打環測試,測試結果顯示端口為up,确定闆卡和(hé)設備運行(xíng)正常,故障在物理(lǐ)線路側。
6. 繼續在運營商光端機端口打環進行(xíng)測試,測試結果顯示接口為down。确定是運營商光端機端口連接故障,調整端口連接。故障排除。
根因
運營商光端機E1端口連接故障。
解決方案
通(tōng)知運營商檢查光端機連接端口,調整到正确端口,故障排除。
建議與總結
通(tōng)過命令逐步檢查狀态和(hé)信息,确定故障根源,建立正确的故障排查思路,運用正确的命令采集相應結果進行(xíng)分析。